Scientific Reports volume 13, Article number: 8559 (2023) Cite this article
186 Accesses
2 Altmetric
Metrics details
Herein, a sensitive and selective spectrofluorimetric method has been developed for the determination of the ocular local anesthetic benoxinate hydrochloride (BEN-HCl) in eye drops and artificial aqueous humour. The proposed method is based on the interaction of fluorescamine with the primary amino group of BEN-HCl at room temperature. Following the excitation of the reaction product at 393 nm, the emitted relative fluorescence intensity (RFI) was measured at 483 nm. The key experimental parameters were carefully examined and optimized by adopting an analytical quality-by-design approach. The method used a two-level full factorial design (24 FFD) to obtain the optimum RFI of the reaction product. The calibration curve was linear at the range of 0.10–1.0 μg/mL of BEN-HCl with sensitivity down to 0.015 μg/mL. The method was applied for analyzing the BEN-HCl eye drops and could also assess its spiked levels in artificial aqueous humour with high % recoveries (98.74–101.37%) and low SD values (≤ 1.11). To investigate the green profile of the proposed method, a greenness assessment was performed with the aid of the Analytical Eco-Scale Assessment (ESA) and GAPI. The developed method obtained a very high ESA rating score in addition to being sensitive, affordable, and environmentally sustainable. The proposed method was validated according to ICH guidelines.
Benoxinate hydrochloride (BEN-HCl), a para-aminobenzoic acid ester of 2-diethylamino ethyl-4-amino-3-butoxy benzoate1, is used as the hydrochloride salt in a 0.4% solution with short ophthalmological procedures2. The purity of BEN-HCl was 99.80 ± 0.6%3. The United States, European, and Japanese Pharmacopoeias all list it as an official medication when administered to the conjunctiva as a local anesthetic agent with less irritation than its analog, tetracaine3,4,5. Its analytical profile involved different techniques, including spectrophotometric6,7,8, electrochemical9, and chromatographic (HPLC and GC)7,10,11 methods. However, due to the high cost of the equipment and excessive solvent type, HPLC and GC are not often used in all laboratories; thus, other simple, rapid, and economical approaches, such as spectroscopy, are required.
In the field of material science, a candidate analytical method, namely spectrofluorimetry, has become a common base for many sensitive determinations12,13,14,15. Its intrinsic sensitivity, rapidity, and wide linear range of detections make the utility of spectrofluorimetry desirable for routine analysis and monitoring16. In this manuscript, we proposed a method for the determination of BEN-HCl based on the interaction of fluorescamine with the BEN-HCl primary amino group in a slightly alkaline pH at room temperature, which produces a strong fluorescent compound. The advantages of using fluorescamine as an amino group derivatizing fluorogenic reagent were the reason behind its use in the proposed method. Fluorescamine has several benefits over other fluorogenic compounds, including simplicity, speed, and the absence of heating requirements. Although the fluorescamine reagent is incredibly dimly fluorescent on its own, it produces a highly fluorescent reaction product (pyrrolone cation) when it reacts with an amino group17. This reaction is pH-dependent and extremely luminous in a slightly alkaline medium because the pyrrolone cation is unsaturated, conjugated, planar, and rigid in structure. In an acidic or strongly alkaline medium, another non-planar and less conjugated derivative is produced.
One of the main goals of analytical laboratories right now is to advance the development of green analytical chemistry (GAC). The twelve basic rules of GAC are the principles on which all greenness assessment tools depend18,19,20. The main goal of GAC is to find a balance between reducing the environmental risks connected to the analytical methodologies and reestablishing the high quality of its output. However, environmental hazards, such as harmful chemicals and/or solvents, energy-wasting machinery, the introduction of large amounts of toxic waste, or anticipated risks to the environment and human health21,22, are needed to be evaluated thoroughly. For this evaluation, many appraisal assessment tools have been designed23. The Analytical Eco-Scale assessment (ESA) and Green Analytical Procedure Index (GAPI)24,25 were utilized to evaluate the greenness profile of the proposed method, which was proved to be excellent green.
Furthermore, the Quality-by-Design (QbD) model makes use of a statistics-based strategy that has many advantages for designing, modifying, and validating the developed method26,27. Compared to univariate procedures, optimization requires significantly less effort, time, and resources. Additionally, by accurately determining significant method variables and providing plots that demonstrate the method's ideal performance and reliability, the development of experimental designs enables a better improvement and understanding of the performance of the developed method28. The attractiveness of QbDs arises from their capacity to identify the most critical factors, categorize them, and analyze their relationships, unlike the univariate techniques behave. The choice of a two-level full factorial design (24 FFD) for this investigation was performed as it is one of the most simple screening designs, enabling the screening of many variables with a limited number of experiments29,30.
Hence, the proposed work aimed to create a green analytical approach with the aid of QbD that could be used to quantify BEN-HCl quickly, safely, and economically in a variety of matrices, including its pure form, eye drops, and artificial aqueous humour. Good selectivity, sensitivity, and simplicity are important features of the present method. The novelty of the current study is addressed in being the first methodology to use fluorescamine as an amino group derivatizing fluorogenic reagent for BEN-HCl by adopting a QbD approach. This study represents a green, economical, and simple analytical solution for the estimation of the studied drug without the need for large volumes of organic solvents or complicated techniques as in HPLC or LC–MS.
Fluorescence spectra were obtained by an FS5 spectrofluorimeter (Edinburgh, UK) accessorized with a 150 W xenon lamp source for excitation and a 1-cm quartz cell. The instrument is accompanied by Fluoracle® software. The speed was 1000 nm/min, and the slit widths were chosen to be 2.0 nm. Switzerland-made analytical digital balance was used. A pH meter (Model; AD1030) from Adwa was used to measure the solutions' pH. The statistical evaluation of the experimental design was performed by Minitab® 16 statistical software (State College, Pennsylvania).
All the reagents and chemicals were of analytical grade. The National Organization for Drug Control and Research (NODCAR), Giza, Egypt, provided benoxinate hydrochloride (BEN-HCl) with a purity of 99.80 ± 0.6%. A 0.4%, w/v (11.6 mM) sterile ophthalmic solution (BENOX®, B. no. MF07) was purchased from a local Pharmacy.
By dissolving 10.0 mg of BEN-HCl in 100.0 mL of ultra-pure distilled water, a standard solution of BEN-HCl (0.1 mg/mL) was made. The calibration graphs and quality control (QC) samples were prepared using this solution. The quality control samples were generated at three concentration levels of 0.1, 0.4, and 1.0 μg/mL, and the calibration curve was obtained using six concentration levels in the range of 0.1–1.0 μg/mL. The solution was found to be stable for at least a week when stored in a cool and dark area.
Fluorescamine dye was purchased from Sigma-Aldrich Company (Germany). It was freshly made in acetone at a concentration of 0.04%, w/v. Boric acid and sodium hydroxide were used to prepare a borate buffer (0.1 M, pH 7.5–9). To imitate the chemical composition of human aqueous humour, artificial aqueous humour was created according to the method reported by Macri et al.31.
A set of calibrated 10-mL measuring flasks was filled with precise volumes of standard BEN-HCl in the concentration range of 0.10–1.0 μg/mL. 1.5 mL of borate buffer (0.1 M, pH 8.2) and 1.0 mL of fluorescamine solution (0.04%, w/v in acetone) were added and mixed thoroughly. The volume was completed to the mark with distilled water and then left to stand for five minutes. The fluorescence of the obtained reaction product was measured at a wavelength of 483 nm after excitation at 393 nm. The same methodology was used in a blank experiment but in the absence of BEN-HCl.
Ultrapure distilled water was used to precisely dilute a specific volume of BENOX® ophthalmic solution, which contains 20 mg of BEN-HCl. The solution was further diluted with the same solvent to obtain a concentration of 100.0 μg/mL. Different samples within the linear range were measured following the procedure under "Generally recommended procedure". The nominal contents of the ophthalmic solutions were calculated using the corresponding regression equation.
Artificial aqueous humour aliquots were placed in a set of 10-mL volumetric flasks (1.0 mL each). The quantitative aliquots of the BEN-HCl working solution were added within the working concentration range, followed by a 2-min vortex mix. The flasks were completed to the volume with distilled water; then, the resulting solution was filtered and analyzed as mentioned in "Generally recommended procedure".
The selectivity, calibration graph linearity, limit of quantification (LOQ), limit of detection (LOD), precision, accuracy, and recovery of the method were all studied. To ascertain the selectivity, five distinct standard BEN-HCl samples spiked in the artificial aqueous humour within the linear range (0.15, 0.30, 0.40, 0.60, and 0.08 µg/mL) were measured. The linearity of the calibration curves was assessed by creating and analyzing standard BEN-HCl samples of known concentrations (over the range of 0.10–1.0 μg/mL with six concentration points) with triplicate measurements for each concentration. The LOD and LOQ were calculated using the following equations:
where S is the calibration curve's slope and σ is the standard deviation of the intercept.
The accuracy and precision were assessed by determining the QC samples thrice at each of the three concentration levels (0.20, 0.40, and 1.00 µg/mL) on each of the three validation days. %RSD was used to calculate the precision, and a percentage of the measured concentration over the nominal concentration was used to calculate the accuracy. The criteria used to determine whether precision was appropriate was that the %RSD did not exceed 15%, and the accuracy was within 15% of the real value32,33. To determine the recovery (extraction efficiency) of BEN-HCl from the pharmaceutical preparations and/or artificial aqueous humour, the fluorescence intensity (FI) of the extracted BEN-HCl was compared to that of pure standards, which represents 100% recovery34.
It was necessary to run initial experiments to assess the feasibility of the experimental design. After examining the impact of various experimental conditions on the fluorescence intensity of BEN-HCl, the most important independent factors were found to be buffer pH, buffer volume, fluorescamine volume, and reaction time. Two trial sets were performed, one at the maximum levels and one at the lower settings, to identify the range for each factor. The chosen range for buffer pH was (7.4–8.2), and that for buffer and fluorescamine volumes were (0.5–1.5 mL) and (0.5–1.0 mL), respectively, and the selected domain for reaction time was (0–5 min). 24 FFD was performed using sixteen designed experiments to investigate the optimal settings that provide the optimal response values (Table 1).
The response (RFI) obtained from each experiment was measured and entered into the Minitab program. Utilizing the response optimizer, the values of both composite (D) and individual (d) desirability were maximized. Next, the most advantageous experimental parameters that produce the best response were ascertained using the optimization plot (Fig. 1). Following that, the study was conducted under the adopted ideal conditions.
24 FFD optimization plots.
The proposed reaction mechanism shown in Scheme 1 illustrates how BEN-HCl reacts with the reagent via its primary aliphatic amino group, stimulating the reagent's fluorescence35,36,37,38,39. The obtained fluorophore emits light at a specific wavelength of 483 nm after its excitation at 393 nm (Fig. 2).
The reported reaction mechanism of BEN-HCl and fluorescamine at a pH of 8.2.
Excitation/Emission spectra of the reaction product of BEN-HCl (0.4 µg/mL), 0.1 M borate buffer (pH = 8.2, 1.5 mL), and fluorescamine (0.04%, w/v (14.0 µM), 1.0 mL).
According to the benefits of analytical QbD, the spectrofluorimetric properties of the fluorescent reaction product and the experimental variables that affect its stability and intensity were investigated and optimized. The buffer volume and buffer pH were shown to be the most important independent variables, while fluorescamine volume (0.04%,w/v) and reaction time were found to be less critical factors. In all the mentioned experiments, BEN-HCl was used at a concentration of 0.4 µg/mL.
From the preliminary trials, the pH effect was examined at the range of 7.0–9.2 (Fig. S1), and the intensity of the obtained product was found to develop only in a slightly alkaline medium and to vanish completely in an acidic medium due to the formation of a non-planar derivative17. As a result, the pH of the study was limited to the range of 7.4–8.2, which allowed the selection of the most suitable borate buffer35,36,37,38. The optimum pH was found to be pH 8.2 (Figs. 1 and 3). In addition, it was observed that the fluorescence intensity dropped as pH raised (Fig. S1) due to the formation of hydroxylated pyrrolone, which is non-planar and less conjugated than cationic pyrrolone with 3D structures40. The impact of borate buffer volume on fluorescence intensity was investigated in the initial trials in the range of 0.5–2.0 mL (Fig. S1). From the obtained results, the selected domain for the design was 0.5–1.5, and the maximum response was obtained with 1.5 mL of the buffer (Figs. 1 and 3). As a result, 1.5 mL of the prepared borate buffer with a pH value of 8.2 was employed throughout the experiment. Furthermore, a volume in the range of 0.3–1.5 of fluorescamine was tested in initial trials (Fig. S1). A volume of 0.5–1.0 mL of fluorescamine (0.04%, w/v; 14.0 µM) was selected as a domain for the design, and the maximum product fluorescence was obtained with 1.0 mL (Figs. 1 and 3). Then, the stability and formation of the final reaction product were tested periodically from 0 to 15 min in the initial trials (Fig. S1). A domain in the range of 0–5 was chosen for the design, and the optimal fluorescence intensity was achieved in approximately 5 min (Figs. 1 and 3), demonstrating how quickly the reaction product is produced, allowing increasing the method throughput analysis. The product's fluorescence was also found to be stable for at least 15 min at room temperature (Fig. S1), which adds another advantage to the developed method. These input ranges were chosen as the most significant effect on the fluorescence intensity of the studied drug was found in the selected ranges.
Surface plots of RFI vs. all pairs of significant independent factors.
According to the initial experiments, the four independent variables were buffer pH, buffer volume, reaction time, and fluorescamine volume, which had the greatest impact on the dependent response (RFI). After identifying the range of each variable as described under "Factorial design" in the Experimental section, 24 FFD was carried out using the sixteen prepared experiments listed in Table 1. The responses from the sixteen experiments were then filled into the Minitab software, where the response optimizer was utilized to maximize the desired response (Table 2). The high composite desirability (D) score of the present study indicates that the conditions are acceptable. The optimization plot (Fig. 1) and the desirability analysis were used to recover the optimum conditions, which were found to be a pH of 8.2, a buffer volume of 1.5 mL, a fluorescamine volume of 1 mL, and a reaction time of 5 min.
One of the most significant benefits of employing QbD is the ability to recognize and evaluate the most significant influencing variables on the dependent response. Further, it enables the analysis of these variables' interactions, which is not achievable using conventional optimization techniques30. Several Minitab plots, including the Pareto Chart, the main effects plot, the normal plot, and the full interaction plot, can be used to do this (Fig. 4). Additionally, utilizing the calculated independent variable coefficients (data in coded units) presented in Table 3 enabled the analysis of the RFI response quantitatively. It was concluded from the main effects plot, Pareto chart, and normal plot (Fig. 4) that reaction time and buffer pH have the greatest significant impact on the RFI. These characteristics have a favorable impact on the RFI, according to the estimated effect values. The interaction between buffer pH, buffer volume, and reaction time also has the most positive impact on the RFI, according to the interaction plot. In contrast, buffer volume showed the least impact on RFI and the least value among the estimated effects (Table 3). The significance of effects was also studied by the analysis of variance (ANOVA), which compares the variability of the effects with an estimation of the experimental error. The obtained results are summarized in Table 4.
(A) 24 FFD Pareto chart of the effects on the RFI at alpha = 0.05, (B) 24 FFD main effects plot for RFI by data means type, (C) 24 FFD normal plot of the effects on the RFI at alpha = 0.05, (D) 24 FFD full interaction plots for RFI by data means type.
Applying Job's continuous variation method41,42 by molar ratios concentrations (1.60 µM), the ratio between the examined BEN-HCl and fluorescamine reagent was calculated. As observed, it was noted that the reaction between them had a molar ratio of 1:1 (Fig. 5). This ratio is consistent with the fact that BEN-HCl possesses one amino group.
Job's method of continuous variation of the reaction between BEN-HCl and fluorescamine (both 1.60 µM) using borate buffer, 0.1 M (1.5 mL, pH 8.2).
The validity of the suggested method was investigated according to the International Council on Harmonization (ICH) Q2/R1 guidelines43; where the linearity range, LOD, LOQ, accuracy, precision, robustness, and selectivity have been established. After measuring the fluorescence intensity using the appropriate BEN-HCl concentration, the developed method exhibited acceptable linearity (r2 = 0.9998) in the concentration range of (0.10–1.0 μg/mL) under ideal reaction conditions. The linearity followed the regression equation y = 123.55x + 288.22. The LOD and LOQ were found to be 0.015 and 0.045 μg/mL, respectively, calculated as discussed in the experimental section.
To evaluate the method's accuracy, three levels of QC concentrations of BEN-HCl (0.20, 0.40, and 1.00 µg/mL) were used. At each concentration, triplicate measurements were performed. According to Table 5, the found % recovery range was 97.0 to 100.6, and the SD ranged from 0.58 to 1.52, indicating the high accuracy of the method.
For the proposed method, two levels of precision, namely, inter- and intra-day precisions, were checked. Three measurements with BEN-HCl concentrations of 0.35, 0.45, and 0.55 µg/mL were measured on the same day, and the other three tests were conducted on the following 2 days. According to Table 6, the resulting % RSD values were found to be less than 2%, demonstrating the high precision of the suggested approach.
The robustness of this method was assessed by investigating the effect of minor variations of the experimental parameters on RFI, including pH (8.2 ± 0.2), buffer volume (1.5 ± 0.5 mL), and fluorescamine volume (1.0 ± 0.3 mL). The obtained values of the calculated concentration were practically expressed as % relative error (%RE). The %RE compares an experimental value to the correct or expected one, expressing the answer as the absolute value of a percentage. A %RE of 0% means that the experimental value was the same as the expected value, and the low value of it indicated the accuracy of the method as well. The intended slight variations had no effect on the RFI, demonstrating the robustness of the suggested method, as shown in Table 7.
Next, the matrix effect was studied, where different spiked aqueous humour samples were prepared to test for the presence of any interference. The proposed method showed high % recoveries (98.74–101.37%) and low SD values (≤ 1.11) without any interference from the excipients or additives, demonstrating the negligible matrix effect (Table 8).
The proposed method was successfully applied to determine BEN-HCl in its eye drops (Benox® eye drops). The average % recoveries for the various concentrations were sufficient, and there was no sign of sample matrix interference, as shown in Table 9. A statistical evaluation of the results of the suggested and reported method7 was performed. When using the Student's t- and F-test with a 95% level of confidence, the estimated values of both variables could not be greater than the theoretical values, as shown in Table 9.
The fixed-time method design was applied to the proposed method to examine BEN-HCl with an artificial, spiked aqueous humour. Certain BEN-HCl concentrations (0.15, 0.3, 0.4, 0.6, 0.8 μg/mL) in the range of the established calibration curve (0.1–1.0 μg/mL) were added to the prepared artificial aqueous humour, and after applying the proposed method, the RFI of each concentration was measured31. High % recoveries in the range of (98.74–101.37%) and low SD values (≤ 1.11), with a correlation coefficient of 0.9998, were obtained, as displayed in Table 8.
Analytical Eco-Scale Assessment (ESA) and Green Analytical Procedure Index (GAPI) are the relatively most popular measures because they are applicable to the majority of analytical techniques. In the current investigation, these assessment tools were used to assess the greenness profile of the developed method.
Analytical ESA, which was created primarily for the quantification of a method's green parameters, is the most useful assessment tool44. It depends on the calculations used to measure the penalty points that were assigned for the developed method based on the types of chemicals and solvents used, potential workplace dangers, the amount of energy used during the process, and the amount of the produced waste. A number (as the outcome of ESA) is produced by subtracting the total penalty points assigned for the method from a rating score of 100.
The tested analytical method gets greener as it gets closer to 100. The outcomes of the proposed method showed a great score of 89 when applied to the eye drops containing BEN-HCl. Consequently, the developed method has proven to be simpler and more eco-friendly. Table 10 provides a detailed description of each Analytical ESA score produced by the proposed method.
The foundation of GAPI is a three-colored phase pictogram made up of five pentagrams. The pentagram used to express each step of the analytical process symbolizes the environmental impact of that step. Three colors, green, yellow, and red, denote the degree of environmental impact. GAPI demonstrates the advantage of combining ESA's benefits because it offers both a brief overview and a thorough analysis of how environmentally friendly various steps of the analytical process are23. GAPI was also used to determine the green property in each step as a semi-quantitative tool. The suggested method produces little waste and needs a small amount of non-toxic chemicals. Additionally, the method is direct and is intended for qualification and quantification. The pictogram in Table 10 shows how the results, which are satisfactory, point to excellent green methodology.
An efficient, rapid, sensitive, and environmentally friendly spectrofluorimetric method was developed to determine BEN-HCl in both commercial eye drops and artificial aqueous humour. The proposed technique is based on fluorescamine's interaction with the primary amino group of BEN-HCl at room temperature. At 483 nm, the RFI of the reaction product was measured after excitation at 393 nm. Adopting an analytical quality-by-design methodology allowed for careful examination and optimization of the crucial experimental parameters. The greenness profile of the developed method was verified using Analytical ESA and GAPI tools. The proposed method eliminates the shortcomings of the previously reported approaches and could be applied for the estimation of the cited drug in quality control laboratories.
The datasets generated and/or analyzed during the current study are available from the corresponding author upon reasonable request.
Galichet, L. Y., Moffat, A., Osselton, M. & Widdop, B. Clarke's Analysis of Drugs and Poisons (Pharmaceutical Press, 2004).
Google Scholar
Brayfield, A. Martindale: The Complete Drug Reference. Electronic Version (Pharmaceutical Press, 2013).
Google Scholar
The United States Pharmacopeia-the National Formulary. (United States Pharmacopeial Convention, 2008).
Council of Europe. European Department for the Quality of Medicines and European Directorate for the Quality of Medicines Healthcare Vol. 8 (Council of Europe, 2013).
Google Scholar
Japanese Pharmacopoeia: Pharmaceuticals and Medical Devices Agency under the Authority of the Ministry of Health. Labour and Welfare (2016).
Abdel-Gawad, F. M. & El-Guindi, N. M. Spectrophotometric determination of metoclopramide and oxybuprocaine through ion pair formation with thiocyanate and molybdenum (V) or cobalt (II). Anal. Lett. 28, 1437–1447 (1995).
Article CAS Google Scholar
El-Gindy, A. First derivative spectrophotometric and LC determination of benoxinate hydrochloride and its degradation products. J. Pharm. Biomed. Anal. 22, 215–234 (2000).
Article CAS PubMed Google Scholar
Merey, H. A., Mohammed, M. A., Morsy, F. A. & Salem, M. Y. Validated spectrophotometric methods for the determination of oxybuprocaine hydrochloride. J. Prog. Res. Chem. 1, 41–53 (2015).
Google Scholar
Shoukry, A., Issa, Y., El-Shiekh, R. & Zareh, M. New ion-selective electrodes for determination of bupivacaine and oxybuprocaine. Anal. Lett. 24, 1581–1590 (1991).
Article CAS Google Scholar
Chorny, M. et al. Development and validation of a stability-indicating high performance liquid chromatographic assay for benoxinate. J. Pharm. Biomed. Anal. 32, 189–196 (2003).
Article CAS PubMed Google Scholar
Kuhlmann, O., Stoldt, G., Struck, H. G. & Krauss, G. J. Simultaneous determination of diclofenac and oxybuprocaine in human aqueous humor with HPLC and electrochemical detection. J. Pharm. Biomed. Anal. 17, 1351–1356 (1998).
Article CAS PubMed Google Scholar
Gauglitz, G. & Vo-Dinh, T. Handbook of Spectroscopy Vol. 1 (VCH Verlag GmbH & Co. KGaA, 2003).
Book Google Scholar
Omar, M. A., Ahmed, H. M., Abdel Hamid, M. A. & Batakoushy, H. A. New spectrofluorimetric analysis of dapagliflozin after derivatization with NBD-Cl in human plasma using factorial design experiments. Luminescence 34, 576–584 (2019).
Article CAS PubMed Google Scholar
Omar, M. A., Ahmed, H. M., Batakoushy, H. A. & Hamid, M. A. A. New spectrofluorimetric analysis of empagliflozin in its tablets and human plasma using two level full factorial design. Spectrochim. Acta A 235, 118307 (2020).
Article CAS Google Scholar
Omar, M. A., Ahmed, H. M., Batakoushy, H. A. & Hamid, M. A. A. Fluorescence spectroscopy for determination of dapagliflozin in pure form and its tablets formulation; Application to content uniformity testing. Spectrochim. Acta A 241, 118642 (2020).
Article CAS Google Scholar
Skoog, D. A., Holler, F. J. & Crouch, S. R. Principles of Instrumental Analysis (Cengage Learning, 2017).
Google Scholar
Stockert, J., Blázquez-Castro, A., Galaz, S. & Juarranz, A. A mechanism for the fluorogenic reaction of amino groups with fluorescamine and MDPF. Acta Histochem. 110, 333–340. https://doi.org/10.1016/j.acthis.2007.10.011 (2008).
Article CAS PubMed Google Scholar
Anastas, P. & Eghbali, N. Green chemistry: Principles and practice. Chem. Soc. Rev. 39, 301–312. https://doi.org/10.1039/b918763b (2010).
Article CAS PubMed Google Scholar
Anastas, P. T. & Kirchhoff, M. M. Origins, current status, and future challenges of green chemistry. Acc. Chem. Res. 35, 686–694. https://doi.org/10.1021/ar010065m (2002).
Article CAS PubMed Google Scholar
Gałuszka, A., Migaszewski, Z. & Namieśnik, J. The 12 principles of green analytical chemistry and the SIGNIFICANCE mnemonic of green analytical practices. Tr. Anal. Chem. 50, 78–84 (2013).
Article Google Scholar
Paul, B. D. A history of the concept of sustainable development: Literature review. Ann. Univ. Oradea Econ. Sci. Ser. 17, 576–580 (2008).
Google Scholar
Sajid, M. & Płotka-Wasylka, J. Green analytical chemistry metrics: A review. Talanta 238, 123046. https://doi.org/10.1016/j.talanta.2021.123046 (2022).
Article CAS PubMed Google Scholar
Tobiszewski, M., Marć, M., Gałuszka, A. & Namieśnik, J. Green chemistry metrics with special reference to green analytical chemistry. Molecules 20, 10928–10946. https://doi.org/10.3390/molecules200610928 (2015).
Article CAS PubMed PubMed Central Google Scholar
Van Aken, K., Strekowski, L. & Patiny, L. EcoScale, a semi-quantitative tool to select an organic preparation based on economical and ecological parameters. Beilstein J. Org. Chem. 2, 3. https://doi.org/10.1186/1860-5397-2-3 (2006).
Article CAS PubMed PubMed Central Google Scholar
Płotka-Wasylka, J. A new tool for the evaluation of the analytical procedure: Green Analytical Procedure Index. Talanta 181, 204–209. https://doi.org/10.1016/j.talanta.2018.01.013 (2018).
Article CAS PubMed Google Scholar
Magdy, G., Abdel Hakiem, A. F., Belal, F. & Abdel-Megied, A. M. A novel quality by design approach for development and validation of a green reversed-phase HPLC method with fluorescence detection for the simultaneous determination of lesinurad, febuxostat, and diflunisal: Application to human plasma. J. Sep. Sci. 44, 2177–2188 (2021).
Article CAS PubMed Google Scholar
Johansson, E., Karlsson, A. & Ludvigsson, J. W. Ultra high performance liquid chromatography method development for separation of omeprazole and related substances on core-shell columns using a quality by design approach. J. Sep. Sci. 43, 696–707 (2020).
Article CAS PubMed Google Scholar
Jadhav, S. B., Reddy, P. S., Narayanan, K. L. & Bhosale, P. N. Development of RP-HPLC, stability indicating method for degradation products of linagliptin in presence of metformin HCl by applying 2 level factorial design; and identification of impurity-VII, VIII and IX and synthesis of impurity-VII. Sci. Pharmaceut. 85, 25 (2017).
Google Scholar
Magdy, G., ElNaggar, M. H., Belal, F. & Elmansi, H. A novel quality-by-design optimized spectrofluorimetric method for the sensitive determination of ricinine alkaloid in edible oils. Food Chem. 404, 134588 (2023).
Article CAS PubMed Google Scholar
Weissman, S. A. & Anderson, N. G. Design of experiments (DoE) and process optimization. A review of recent publications. Org. Process Res. Dev. 19, 1605–1633 (2015).
Article CAS Google Scholar
Macri, A. et al. An artificial aqueous humor as a standard matrix to assess drug concentration in the anterior chamber by high performance liquid chromatography methods. Clin. Lab. 61, 47–52 (2015).
Article CAS PubMed Google Scholar
Food and Drug Administration (FDA). Guidance for Industry: Bioanalytical Method Validation 1–25 (US Department of Health and Human Services, 2013).
Google Scholar
Shintani, Y., Zhou, X., Furuno, M., Minakuchi, H. & Nakanishi, K. Monolithic silica column for in-tube solid-phase microextraction coupled to high-performance liquid chromatography. J. Chromatogr. A 985, 351–357 (2003).
Article CAS PubMed Google Scholar
El Hamd, M. A. et al. Simultaneous determination of propofol and remifentanil in rat plasma by liquid chromatography-tandem mass spectrometry: Application to preclinical pharmacokinetic drug-drug interaction analysis. Biomed. Chromatogr. 29, 325–327. https://doi.org/10.1002/bmc.3281 (2015).
Article CAS PubMed Google Scholar
Walash, M. I., Belal, F., El-Enany, N. & El-Maghrabey, M. H. Simple and sensitive spectrofluorimetric method for the determination of pregabalin in capsules through derivatization with fluorescamine. Luminescence 26, 342–348 (2011).
Article CAS PubMed Google Scholar
Aydoğmuş, Z. Simple and sensitive spectrofluorimetric method for the determination of oseltamivir phosphate in capsules through derivatization with fluorescamine. J. Fluoresc. 19, 673–679 (2009).
Article PubMed Google Scholar
Tekkeli, S. E. K., Önal, A. & Sağırlı, A. O. Spectrofluorimetric determination of tobramycin in human serum and pharmaceutical preparations by derivatization with fluorescamine. Luminescence 29, 87–91 (2014).
Article CAS PubMed Google Scholar
Belal, F., Abdine, H., Al-Majed, A. & Khalil, N. Spectrofluorimetric determination of vigabatrin and gabapentin in urine and dosage forms through derivatization with fluorescamine. J. Pharm. Biomed. Anal. 27, 253–260 (2002).
Article CAS PubMed Google Scholar
Singer, V. L. & Haugland, R. P. In Fluorescent and Luminescent Probes for Biological Activity (ed. Mason, W. T.) 51–62 (Academic Press, 1999).
Chapter Google Scholar
Udenfriend, S. et al. Fluorescamine: A reagent for assay of amino acids, peptides, proteins, and primary amines in the picomole range. Science 178, 871–872. https://doi.org/10.1126/science.178.4063.871 (1972).
Article ADS CAS PubMed Google Scholar
Hill, Z. D. & MacCarthy, P. Novel approach to Job's method: An undergraduate experiment. J. Chem. Educ. 63, 162. https://doi.org/10.1021/ed063p162 (1986).
Article CAS Google Scholar
Carmody, W. R. Demonstrating Job's method with colorimeter or spectrophotometer. J. Chem. Educ. 41, 615 (1964).
Article CAS Google Scholar
ICH Harmonised Tripartite: Validation of analytical procedures: Text and methodology. Q2 (R1) 1, 05 (2005).
Gałuszka, A., Migaszewski, Z. M., Konieczka, P. & Namieśnik, J. Analytical Eco-Scale for assessing the greenness of analytical procedures. Trends Anal. Chem. 37, 61–72 (2012).
Article Google Scholar
Download references
The authors are thankful to the Researchers Supporting Project number (RSP2023R516) at King Saud University, Riyadh, Saudi Arabia. The authors would like to thank the Deanship of Scientific Research at Shaqra University for supporting this work.
Department of Pharmaceutical Sciences, College of Pharmacy, Shaqra University, Shaqra, 11961, Saudi Arabia
Mohamed A. El Hamd
Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, South Valley University, Qena, 83523, Egypt
Mohamed A. El Hamd
Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, 35516, Egypt
Mahmoud El-Maghrabey
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Kafrelsheikh University, Kafrelsheikh, 33511, Egypt
Galal Magdy
Department of Pharmaceutics, College of Pharmacy, King Saud University, Riyadh, 11451, Saudi Arabia
Wael A. Mahdi & Sultan Alshehri
Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Menoufia University, Shebin Elkom, 32511, Egypt
Amr K. A. Bass
Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Menoufia University, Shebin Elkom, 32511, Egypt
Hany A. Batakoushy
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
M.A.E.: Conceptualization, Methodology, Data curation, Validation, Writing-original draft. M.E.: Conceptualization, Data curation, Validation, Writing-review & editing. G.M.: Methodology, Data curation, Validation, Writing-review & editing. W.A.M. & S.A.: Resources, Writing-review & editing. A.K.A.B.: Visualization, Writing-review & editing. H.A.B.: Conceptualization, Methodology, Formal Analysis, Visualization, Validation, Writing-original draft. All authors approved the manuscript for publication.
Correspondence to Mohamed A. El Hamd, Mahmoud El-Maghrabey, Galal Magdy or Hany A. Batakoushy.
The authors declare no competing interests.
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
Reprints and Permissions
El Hamd, M.A., El-Maghrabey, M., Magdy, G. et al. Application of quality-by-design for adopting an environmentally green fluorogenic determination of benoxinate hydrochloride in eye drops and artificial aqueous humour. Sci Rep 13, 8559 (2023). https://doi.org/10.1038/s41598-023-35347-6
Download citation
Received: 03 April 2023
Accepted: 16 May 2023
Published: 26 May 2023
DOI: https://doi.org/10.1038/s41598-023-35347-6
Anyone you share the following link with will be able to read this content:
Sorry, a shareable link is not currently available for this article.
Provided by the Springer Nature SharedIt content-sharing initiative
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.